The T960-A Touch Thermal Cycler offers unmatched performance with fast and accurate results; thanks to its advanced interface it allows new ways to optimize operational protocols and meet the needs of each researcher.
Choice of multiple interchangeable reaction modules, intuitive Touch Screen graphic interface, optimize PCR tests with the use of gradient mode, transport your files and data on a common USB pen connected to your laptop / PC for remote and future monitoring upgrade ...
What else can you ask for from a Thermal Cycler?
High Performance
The T960 gradient thermal cycler allows a heating rate of up to 5 ° C / s and an accuracy of <= ± 0.1 ° C, for fast and quality PCR.
Thanks to the most advanced Peltier technology and the materials used, it guarantees amplification speed, accuracy of results and reliability.
The gradient function is thus supported by a high stability system and a gradient temperature of excellent linearity.
Windows CE operating system
The T960 model uses the Windows CE operating system, for an intelligent instrument with over 100 self-diagnostic functions, automatic software start when the instrument is switched on and intuitive management.
Touch Screen Interface
Menu management via large 7 'Touch Screen LCD display, for quick and total control of settings. Simple, intuitive, it allows rapid learning of the management software and puts PCR programming at your fingertips.
Agenda
Possibility of entering appointments for programming the use of the T960 thermal cycler, optimizing the use of the same by multiple operators, with alarm systems included.
USB connection
The USB port allows the use of pendrive for data exchange and connection with a mouse (included with the instrument) which allows you to completely manage the software, alternatively to the Touch Screen control, all within a "click".
Flexibility
Thanks to the wide availability of blocks, single for 0.2ml tubes, 0.5ml tubes, mixed 0.2ml and 0.5ml up to the possibility of choosing the block for 384-well plates, the T960 is the ideal instrument for every type of laboratory and application. The lid is adjustable according to the type of media used, 0.2ml tubes with flat or domed cap, 0.5 tubes and 384-well plate for optimal temperature maintenance.
Practicality
Possibility to subsequently purchase blocks with different capacities without having to purchase a new instrument. Easy interchangeability of the same thanks to the quick and safe block extraction system.
PCR Reaction Modules:
T960-A Touch thermal cycler is complete with holds 96x0.2 ml tubes module or one 96-well 0.2 ml plate, alternatively the following are available:
54-well eaction module, gradient enabled |
Holds 54x0,5 ml tubes |
96-well+77-well reaction module, gradient enabled |
Holds 96x0,2 ml tubes, one 96-well plate or 77x0,5 ml tubes |
384-well reaction module |
Holds one 384-well plate |